DC Input |
Max.PV input power (kW) |
9 |
12 |
15 |
18 |
22.5 |
Max. PV voltage (V) |
1,000 |
MPPT voltage range (V) |
180~850 |
Full power MPPT voltage range (V) |
250~850 |
330~850 |
430~850 |
510~850 |
620~850 |
Min. input voltage/start-up voltage (V) |
125/180 |
Max. input current per MPPT (A) |
13/13 |
Max. short-circuit current (A) |
16/16 |
16/16 |
16/16 |
16/16 |
25/25 |
Number of MPPT rackers |
2 |
No. of strings per MPPT trackers |
1/1 |
Rated PV input voltage (V) |
700 |
AC Output |
Nominal output power to grid (kVA) |
6 |
8 |
10 |
12 |
15 |
Max. apparent power to grid (kVA) |
6.6 |
8.8 |
11 |
13.2 |
16.5 |
Max. apparent power from grid (kVA) |
13.2 |
17.6 |
22 |
26.4 |
33 |
Max. apparent current from grid (A) |
19.1 |
25.5 |
31.8 |
38.2 |
47.6 |
Nominal output current to grid (A) |
8.7 |
11.5 |
14.4 |
17.3 |
21.7 |
Max.output current to grid (A) |
9.5 |
12.7 |
15.9 |
19.1 |
23.8 |
Nominal grid voltage (V) |
380/400,3W+N+PE |
Nominal grid frequency (Hz) |
50/60 |
THDi |
<3% |
Battery |
Max.charging /discharging Power (kW) |
6.6 |
8.8 |
11 |
13.2 |
16.5 |
Battery voltage range (V) |
125~600 |
Battery optimal operating voltage
range (V) |
150~550 |
Max.charging /discharging current (A) |
50 |
Rated.charging /discharging current (A) |
40 |
Battery type |
Lithium and Lead Acid Battery |
Communication interface |
CAN |
EPS output |
Nominal output power (kVA) |
6 |
8 |
10 |
12 |
15 |
Max. apparent power (kVA) |
6.6 |
8.8 |
11 |
13.2 |
16.5 |
Nominal output current (A) |
8.7 |
11.5 |
14.4 |
17.3 |
21.7 |
Max.output current (A) |
9.5 |
12.7 |
15.9 |
19.1 |
23.8 |
Nominal output voltage (V) |
400 ,3W+N+PE |
Nominal output frequency (Hz) |
50/60 |
THDu |
<2% |
Max.efficiency |
97.9% |
97.9% |
98.2% |
98.2% |
98.5% |
Europe efficiency |
97.2% |
97.2% |
97.5% |
97.5% |
97.6% |
MPPT efficiency |
≥99.5% |
Max.battery charge/discharge efficiency |
97.5% |
97.5% |
97.5% |
97.6% |
97.8% |
General Data |
Ingress protection |
IP65 |
Operating temperature range (℃) |
-25~60 |
Relative humidity |
0~95% |
Operating altitude (m) |
2,000 (>2,000 Derating) |
Dimensions W*H*D (mm) |
566*596*220 |
Weight (kg) |
32 |
Self-consumption at night (W) |
<15 |
Cooling |
Natural |
Noise emission (dB) |
≤35 |
EMC |
IEC/EN 61000-6-1:2019, IEC/EN 61000-6-2:2019, IEC/EN 61000-6-3:2021, IEN/EN 61000-6-4:2019, IEC/EN 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021, IEC/EN 61000-3-11:2019, EN 61000-3-12:2011 |
On-grid |
Europe: EN 50549-1:2019/AC:2019, Poland:EN50549-1:2019/Rfg:2016/NC Rfg:2018/PTPiREE:2021, Germany: VDE-AR-N 4105:2018 /DIN VDE V 0124-100(VDE V 0124-100):2020, South Africa: NRS 097-2-1:2017 Edition 2.1, UK:G98/G99/1-6:2022, Spain:UNE217001:2020 /UNE217002:2020/NTS V2.1:2021-07, IEC61727:2004/IEC62116:2014/IEC61683:1999, Hungary:EN50549-1:2019/RFG:2016/Hungary, Italy CEI 0-21 |
Safety standard |
IEC/EN62109-1:2010, IEC/EN62109-2:2011 |
Display and communication |
HMI |
LCD; APP |
BMS |
CAN |
EMS/Meter |
RS485/RS485 |
Supported communication interface |
WIFI / GPRS |